Vertiq 23-14 920Kv

Vertiq UP12 11V

Philadelphia, PA USA | 15m | 2023-09-15 | 23.9 C | 30.01 in Hg | 48.9% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W)
1.0 11.0 0.1 1 880 0.00 37.1 20 24.4
2.0 11.0 0.3 4 1740 0.01 64.7 70 19.8
3.0 11.0 0.9 10 2560 0.03 75.2 160 16.4
4.0 11.0 1.9 21 3342 0.05 79.1 280 13.5
5.0 10.9 3.4 37 4086 0.07 80.3 410 11.1
6.0 10.9 5.5 59 4789 0.09 80.1 550 9.3
7.0 10.8 8.1 88 5421 0.12 78.9 700 8.0

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.